Biebesheim => Deutsch => images
Monument type
Presumed burial ground
Survey data
Area investigated: 100 m x 50 m
Resolutions: 1 MP/m2 (a = 0,50 m) : 5.000 m2
Array configuration: Twin-probe
Measuring instruments: Lippmann 4point light MC
Imaging software: SURFER (Golden Software)
Survey period: 02.2020 and 07.2020
Comments
In this survey extreme noise made the use of strong filters necessary.
However, the results only allow an uncertain interpretation of the measurement images.
An
initially assumed malfunction of the measuring device as the reason for
the high level of noise could be ruled out by an almost identical
follow-up measurement five months later.
Since the entire measuring area was very heavily crisscrossed and
undermined by root vole tunnels, it seems reasonable to assume that the
cause of the noise is to be found in the extremely inhomogeneous and
loosened soil.